D230
multi-channel data-logger for pH, mV, ion,
conductivity, TDS, dissolved oxygen and temperature |


|
Built
in a standard 19 inch rack + cabinet the central unit accepts up to
7 modules. Different modules can be mixed in one unit.
There are two modules available:
D291: 4 pH/mV/Ion/dissolved oxygen + 4 temperature channels,
D292: 4 conductivity/TDS + 4 temperature channels.
Up to 16 units can be combined with each other to increase the number
of channels up to 448.
All parameters including set-up, calibration and display are controlled
through any computer via a single RS232 connection.
All necessary GLP-procedures are on board. The software package supplied
with the D230 is specially designed to control, collect and store
data. Runs under Windows 2000 or higher. All channels are processed
at the same time, each in its own window. The software automatically
detects the maximum number and type of available channels.
Data is collected on-line with a programmable interval (4 s ... 24
h).
Documented printouts will show file name, date and time, name of the
operator, name of the company, name of the division, optional notes
by the operator.
Password protection prevents any unauthorised access to the instrument.
D291
pH: 0...14 pH
mV: ± 2000 mV
Ion: 0.01 ng/l...99.9 g/l
Dissolved oxygen: 0...60 mg/l, 0...600%
Temperature: -30...+130°C
Resolution: 0.001 pH, 0.1 mV, 0.01 mg/l, 0.1°C
D292
Conductivity: 0...2000 mS/cm
TDS: 0...100 g/l
Resolution: 0.01µS/cm, 0.01 mg/l, 0.1° |
|
| Download leaflet
| Download manual
| |
|
|
| |
C3060 - C3061
multi-channel data-logger for pH, mV, ion, conductivity,
resistivity, salinity, TDS, dissolved oxygen and temperature |

|
8
independent channels for all measurements !
(conductivity and temperature: only 2 channels)
A large bright LCD screen with white backlight
enables to view all channels simultaneously.
Multi-point (1...5) calibration of pH electrodes with any of eleven
pre-programmed and five user specified buffer tables.
Multi-point (1...3) calibration of conductivity electrodes for increased
linearity with any of three pre-programmed or user specified standard
tables.
Multi-point (2...5) calibration + blank correction of ion-selective
electrodes.
The display guides you at any moment in the language of your choice
(English, Dutch, French, German).
All necessary GLP-procedures are on board.
Password protection prevents any unauthorised access to the instrument.
Three year warranty.
Storage memory for up to 12000 values + date and time.
Two-way communication with any computer using USB (C3060).
Two-way communication with any computer using
Ethernet (C3061). NEW !
RS232 interface for connection to a printer.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC) or 9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to work
in a car.
Free data acquisition software enables to view, store and edit the
measurements in your computer.
Specifications
pH: -2...+16 pH
mV: ± 2000 mV
Ion: 10-11...10+1, any unit
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
Salinity: 0...70 ppt
TDS: 0...100 g/l
Temperature: -5...+105°C
Resolution: 0.001 pH, 0.1 mV, 0.001 µS/cm, 1 ohm.cm,
0.01 mg/l, 0.1 ppt, 0.1°C |
|
| Download leaflet
| Download manual
| |
|
|
| |
DIS-1
data acquisition software for meters or controllers equipped with
a USB, Ethernet or RS232 interface |


|
This
software package is specially designed to collect and store data from
the following models:
C3010, C3011, C3020, C3021, C3030, C3031, C3040, C3041, C3050, C3051, C3060, C3061.
C931, C932, C933, K912.
T871, T872.
It can also be used with the following previous models or versions:
C861, C862, C863, C864, C868.
C831, C832, C833, C834, C835, C838, C731, C732, C733.
P901, P902, P903, K911, Z921.
R305, R315, R325, R335, R735.
T851, T852.
Runs under Windows 2000 or higher.
Allows to log, view and print the incoming values in real time or
to retrieve data-logged values from the memory of the instrument.
All channels of multi-channel instruments can be processed simultaneously.
Values are shown in separate windows, tables or graphs.
A graph window also allows to set alarm limits and to view several
statistic values.
Guides you at any moment in the language of your choice (English,
Dutch, French). |
|
| Download leaflet
| |
|
|
| |
DIS-2
data acquisition software for controllers equipped with a RS485
interface |
 |
Special
software to transfer data from the following models to a personal
computer:
R362, R363
It can also be used with the following previous models or versions:
R305, R315, R335.
Runs under Windows 2000 or higher.
Allows to log, view and print the incoming values in real time or
to retrieve data-logged values from the memory of the instrument.
Up to 31 controllers can be processed simultaneously.
Values are shown in separate windows, tables or graphs.
A graph window also allows to set alarm limits and to view several
statistic values.
Guides you at any moment in the language of your choice (English,
Dutch, French). |
|
Download
leaflet |
|